Product Features

MetraSCAN 3D™
The most flexible portable 3D measurement solution engineered for shop floor conditions

Industries

  • Aerospace
  • Automotive/Transport
  • Consumer Products
  • Heavy Industries
  • Manufacturing
  • Power Generation
  • Research and Education

Applications

Inspection:

  • Part-to-CAD analysis
  • First article inspection
  • Supplier product quality inspection
  • Conformity assessment of 3D models against original parts or production tooling
  • Conformity assessment of manufactured parts against originals
  • Alignment
  • Tooling certification

Reverse Engineering:

  • 3D scan-to-CAD
  • 3D modeling
  • Tooling and jig development
  • Maintenance, repair and overhaul (MRO)
  • Finite element analysis (FEA)

Technical Specifications

MetraSCAN 750™ MetraSCAN 750™​|Elite
Accuracy (1) Up to 0.030 mm (0.0012 in.)
Volumetric Accuracy (2) 9.1 m3
(320 ft3) (3)
0.086 mm
(0.0034 in.)
0.064 mm
(0.0025 in.)
16.6 m3
(586 ft3) (3)
0.122 mm
(0.0048 in.)
0.078 mm
(0.0031 in.)
Volumetric Accuracy
(with MaxSHOT 3D or C-Link) (4)
0.060 mm + 0.025 mm/m
(0.0024 in. + 0.0003 in./ft.)
0.044 mm + 0.025 mm/m
(0.0017 in. + 0.0003 in./ft.)
Resolution 0.050 mm (0.0020 in.)
Measurement Rate 480,000 measurements/s
Part Size Range(recommended) 0.2–6 m (0.7–20 ft.)
Stand-off Distance 300 mm (11.8 in.)
Depth-of-field 200 mm (7.9 in.)
Scanning Area 275 x 250 mm (10.8 x 9.8 in.)
Light Source 7 laser crosses (+ 1 extra line)
Laser Class 2M (eye-safe)
Weight 1.38 kg (3.0 lbs.)
Dimensions 289 x 235 x 296 mm (11.4 x 9.3 x 11.7 in.)
Connection Standard 1 x USB 3.0
Software VXelements™
Output Formats .dae, .fbx, .ma, .obj, .ply, .stl, .txt, .wrl, .x3d, .x3dz, .zpr
Operating Temperature Range 5–40°C (41–104°F)
Operating Humidity Range(non-condensing) 10–90%
Certifications EC Compliance (Electromagnetic Compatibility Directive, Low Voltage Directive, RoHS 2 Substance Restrictions Directive), IP50, WEEE

(1) Typical value for diameter measurement on a calibrated sphere artefact.

(2) Performance is assessed with traceable length artefacts by measuring these at different locations and orientations within the working volume of the C-Track (value = maximum deviation).

(3) The volumetric accuracy performance of the MetraSCAN 3D is dependent on the working volume in which the measurement is made: 9.1 m3 (320 ft3) or 16.6 m3 (586 ft3).

(4) The volumetric accuracy performance of the system when using a MaxSHOT 3D cannot be superior to the default volumetric accuracy performance for a given model.



MetraSCAN 350™ MetraSCAN 350™​|Elite
Accuracy (1) Up to 0.040 mm (0.0016 in.)
Volumetric Accuracy (2) 9.1 m3
(320 ft3) (3)
0.086 mm
(0.0034 in.)
0.064 mm
(0.0025 in.)
16.6 m3
(586 ft3) (3)
0.122 mm
(0.0048 in.)
0.078 mm
(0.0031 in.)
Volumetric Accuracy
(with MaxSHOT 3D or C-Link) (4)
0.060 mm + 0.025 mm/m
(0.0024 in. + 0.0003 in./ft.)
0.044 mm + 0.025 mm/m
(0.0017 in. + 0.0003 in./ft.)
Resolution 0.050 mm (0.0020 in.)
Measurement Rate 205,000 measurements/s
Part Size Range (recommended) 0.2–6 m (0.7–20 ft.)
Stand-off Distance 300 mm (11.8 in.)
Depth-of-field 200 mm (7.9 in.)
Scanning Area 225 x 250 mm (8.8 x 9.8 in.)
Light Source 3 laser crosses
Laser Class 2M (eye-safe)
Weight 1.38 kg (3.0 lbs.)
Dimensions 289 x 235 x 296 mm (11.4 x 9.3 x 11.7 in.)
Connection Standard 1 x USB 3.0
Software VXelements™
Output Formats .dae, .fbx, .ma, .obj, .ply, .stl, .txt, .wrl, .x3d, .x3dz, .zpr
Operating Temperature Range 5–40°C (41–104°F)
Operating Humidity Range (non-condensing) 10–90%
Certifications EC Compliance (Electromagnetic Compatibility Directive, Low Voltage Directive, RoHS 2 Substance Restrictions Directive), IP50, WEEE

(1) Typical value for diameter measurement on a calibrated sphere artefact.

(2) Performance is assessed with traceable length artefacts by measuring these at different locations and orientations within the working volume of the C-Track (value = maximum deviation).

(3) The volumetric accuracy performance of the MetraSCAN 3D is dependent on the working volume in which the measurement is made: 9.1 m3 (320 ft3) or 16.6 m3 (586 ft3).

(4) The volumetric accuracy performance of the system when using a MaxSHOT 3D cannot be superior to the default volumetric accuracy performance for a given model.